Products
Profiler
T4
T6V4
RTD6
GP4
GP8
VB1
VB1000T
VB2000T






Click Here
.

MMS3000 SERIES

At a Glance...
GP4 and 8


Drop-down menu navigation.

Constant background monitoring.

Sleep Mode for extended recordings.

Greater Math Functions in MAS™.

User adjustable span/offset settings.

Event/Time-based triggerd recordings.

Folder-based file management.

Long-life Nicad battery pack.

24 bit A/D converter.

ProFlash upgradeable firmware.

MAS™ Windows based software.

CE approved.

512 Kilobyte non volatile memory. (Approx 400,000 samples)

4.3"x2.3" (100mmx60mm) LCD screen.

Long-life Nicad battery pack.

RS232 Interface with cable.

3 Year Warranty (on instrument only).
MMS3000 RTD6

Engineers require data recording instruments that are truly flexible, that quickly and easily adapt to a variety of measurement applications. At the same time, Accountants and Financial Controllers demand the most stringent use of data acquisition and instrumentation funds - a constraint that often excludes the most convenient and useful products on the market. Now with the MMS3OOO-GP Series, Engineers and Accountants can both finally agree on the same product.

The MMS3000-GP Series combines all the usual benefits of low-cost and ease-of-use found in single-purpose data loggers coupled with the power and sophistication of more expensive rack-mount systems. The MMS3000-GP Series allows you to measure and record a variety of measurement parameters in a single session. Each 4-20mA input channel can be individually scaled to measure, display and record data in the engineering units of your choice. A menu of commonly used engineering units is available for quick selection, but greater flexibility is achieved by allowing the user to also create your own units with simple text entry from the MMS3000 keypad. Along with your standard transducers the MMS3000-GP Series can measure, display and record virtually anything.

Do you need to review data in the field or on the plant floor away from the PC? Then the MMS3000-GP4 and GP8 are your instruments of choice. The large LCD enables you to graphically review recorded data by simply pressing a few keys.


MAS screen shots
Windows based software for flexible data manipulation.
Producing a variety of graphs and printout options.

Wouldn't it be a welcome change to have a single easy-to-use product that is flexible enough to suit all your data logging needs?

The MMS3000-GP Series is the answer you have been looking for. Below are some of the many Process Variables that are compatible with the MMS3000-GP Series:



Pressure

Temperature

Relative Humidity

Light Intensity

Flow Rate

Level / Depth

Displacement

Velocity

Force / Load

pH

Position

Power / Current / Voltage
Available for Download

User Manual

Product Specification PDF Document

Software/Firmware
Specifications
ITEM
SPEC
REMARKS

Model: MMS3000-GP4 & GP8
4 & 8 Current Loop Input Channels with General Purpose Converstion Software


  CURRENT RANGE
Nominal current range
4 to 20mA
4mA corresponds to 0 units (units selectable in software), 20mA corresponds to full-scale indication.
Maximum current range
3.2 to 24mA
Offset and span are user-adjustable.
  CURRENT RESOLUTION

2µA (1 part in 2,000 @ 4mA, 1 part in 10,000 @ 20mA)

  CURRENT ACCURACY

?0.1% of reading ?5µA
Offset and span calibrated to nominal values. Instrument temperature 73 ?18°F (23 ?10°C).
  ENGINEERING UNITS
Units
Metric and Imperial units for temperature, displacement, force, pressure, voltage, current, plus percentage.
User can create custom Engineering Units.
Scaling
pico, nano, micro, milli, kilo, mega, giga, tera
Units and scaling are user-configurable.
  MINIMUM SAMPLING INTERVAL

Number of channels selected
(User-selectable)

Minimum sampling time
(Seconds)

GP4
GP8

1
1
0.2
2
2
0.3
3
3
0.5
4
4
0.6

5
0.7

6
0.8

7
0.9

8
1.0
Minimum time to scan all selected channels, not each channel.

Sampling interval is programmable from 0.2 seconds to 60 hours.

Model GP4 has 4 channels only.

  DATA LOGGING
Data Storage Format
Up to 50 named folders
User-specified name entered from keypad.

Multiple files per folders
Each file has unique time and date stamp.

Up to 59,999 data points per file
MAS plots limited to 15,000 samples per channel.
Data Storage
512 kilobytes ?approximately 400,000 individual samples
Non-volatile memory (with battery backup).
Folder Name
Up to 16 alphanumeric characters
Number of samples depends on number of folders and files.
  DISPLAY

LCD with graphic capabilities

Resolution
240 x 128 pixels

Viewing Area
4.3" x 2.3" (110mm x 60mm)

Backlight
Electro-luminescent

 PROFLASH

Allows internal firmware to be upgraded via built-in serial port
Download firmware upgrades via the Internet
 COMMUNICATIONS

RS232 - 15kV ESD Protected.
Cable with DB9 connector included
Baud Rate
9600, 19200, 57600 bits per second
Automatic Baud Rate Selection
  INPUT TERMINATION

Screw Terminals, 5mm pitch, 2.5mm wire size
4 pairs for model GP4, 8 pairs for model GP8.
  LOOP BURDEN

Maximum 6 Volts at 20mA loop current

  ISOLATION

Optically Isolated
Between each current loop input and between each current input and instrument outputs e.g. RS232 port. The instrument is not intended for connection to "live" surfaces (voltage exceeding 50 VDC or 32 VAC).
  BATTERY
Type
Custom Nickel-Cadmium pack

Voltage
7.2 Volts nominal

Capacity
1500 mAh nominal

Operating Time
13 hrs with backlight off, 7 hrs backlight on - nominal

  CHARGER AND CONDITIONER

Built-in dual rate charger ?Automatic and Manual control
AC Adapter included (13.5 ?1.5 VDC, 1A output)
Fast Charge Rate
0.7A nominal
2.5 hours for complete charge nominal
Discharge Rate
0.5A nominal
Combats NiCad battery memory effect
  MECHANICAL
Size
9.7"W x 6.1"L x 3.0"H (247mm x 154mm x 75mm)
Including protective boot
Weight
4.4lb (2kg)
Including protective boot and strap
  ENVIRONMENTAL
Temperature/Humidity


Operating
32°F to 122°F (0°C to 50°C) / 70% RH
Non-condensing

32°F to 86°F (0°C to 30°C) / 80% RH
Non-condensing
Storage
14°F to 140°F (-10°C to 60°C ) / 95% RH

EMC
EN50081-1
Radiated and conducted emissions

EN50082-1
ESD Immunity and RF field immunity (EMI).
The manufacturer reserves the right to modify specifications without prior notice.